NIK 2307

Three-phase meter

  • Two interfaces
  • GPRS/LTE
  • Active and reactive energy
  • Instant values of power, voltage, amperage
  • 4 tariffs / 12 zones
  • Modern communication interfaces
  • Additional interface
  • Optical port
  • Disconnector
  • Sensors of magnetic and electromagnetic fields
  • Tamper sensor for case and terminal cover
  • Transparent / not transparent case (optional - integral)
  • Battery mode (optional - two batteries),
    connecting an external power supply
  • Measurement with accuracy class 0.5 S
  • Voltage quality control
Meter type

Electronic, Electronic

Number of phases

Three-phase, Three-phase

Active / reactive energy:

AR, AR

Accuracy class of active energy measurement:

0,5 S, 0,5 S

Fraud protection

Electromagnetic field indication, Indication of the magnetic field, Mechanical intervention sensors, Mechanical intervention sensors, Electromagnetic field indication, Indication of the magnetic field

Interfaces

Ethernet, GSM, Optical port, PLC, RF 2,4 Ghz, RS-485, Ethernet, GSM, PLC, RF 2,4 Ghz, RS-485, Optical port

Tariffs

Tariff

Reserve power supply

2 batteries, 2 batteries, Connecting an external power supply, Battery mode, Connecting an external power supply

Prepayment function

There is prepayment function, There is prepayment function

Options

Indication of incorrect connections, Load disconnection relay, Voltage quality control, Indication of incorrect connections, Voltage quality control, Load disconnection relay

Design features

Non-transparent body, One-piece case, Optoport cover protection, Split case, Transparent case, Transparent terminal cover, Optoport cover protection, Non-transparent body, One-piece case, Transparent terminal cover, Transparent case, Split case

Quantity of measuring elements

3, 3

Three-phase meter

Specifications

Accuracy class for measuring of active energy:
EN 62053-21 1
EN 62053-22 0,5 S (for transformer connection)
Accuracy class for measuring of reactive energy:
EN 62053-23 2
Nominal voltage 3х220/380 V
3х230/400 V
3х240/416 V
3х57,7/100 V (for transformer connection)
3х57,7/100 V … 3×240/416 V (wide range, for transformer connection)
Operation voltage range -20 … +15%
Nominal frequency 50 Hz
Nominal current 5 А
Maximum current 10 A; 80 A; 120 A
Meter constant 8000 imp / (kW*h)
Starting current for measuring of active energy :
for meters of direct conection class 1,0 12,5 mА
for meters of transformer conection class 1.0 (0.5 S) 10 mА (5 mА)
Starting current for measuring of reactive energy :
for meters of direct conection class 1,0 15,6 mА
for meters of transformer conection class 1.0 (0.5 S) 15,0 mА (9,3 mА)
Power consumption, no more:
in the voltage circuits without PLC interface 10 V•A (2 W)
in the voltage circuits with PLC interface 20 V•A (5 W)
in current circuits 0,05 V•A
Operating temperature -40 … +70 °C
Protection level ІР 54
Weight, no more than 2,3 kg
Number of digits on LCD 6 + 2
Service life 24 years

 

Dimensions

Table of construction types